Building a safe room for your home or small business fema s safe room guidance also references criteria in icc 500 standard for the design and construction of storm shelters.
Fema approved storm shelter doors.
Securall tornado doors are constructed in accordance with federal emergency management agency fema recommended design specifications.
Fema p 361 offers best practices on the design and construction of safe rooms but fema does not regulate construction.
Steel is the most prevalent door material to pass fema p 361 and icc 500.
Guidance for community and residential safe rooms fema p 361 safe room resources cd accompanying resources fema p 388 cd tornado protection.
Icc 500 is the standard for the design and construction of storm shelters.
Guidance for community and residential safe rooms 2015 stormpro icc 500 2014 tornado selection guide find technical information here.
Take a look at testing videos below and see for yourself how our fema approved tornado storm shelters will withstand even the strongest storms.
No wood door with or without metal sheathing has successfully passed fema p 361.
We also specialize in above ground saferoom doors and frames that are constructed in accordance with the federal emergency management agency s fema guidelines and the international code council s icc 500 standard for tornado shelter doors.
Fema p 320 taking shelter from the storm.
Tornado shelter door is a critical element when designing a safe room for protection against severe storms.
All of our storm shelters have been thoroughly impact tested at the wind science engineering research center at texas tech university and exceed fema standards.
Fema storm shelter doors and hardware for in residence tornado shelters safe rooms.
Building a safe room for your home or small business 2014 fema p 361 safe rooms for tornadoes and hurricanes.
Tornado assembly components are approved and certified as an assembly and cannot be mixed and matched.
Building a safe room for your home or small business fema l 233 brochure safe rooms for tornadoes and hurricanes.
Fema b5 2 3 icc 500 sec 503.
Selecting refuge areas in buildings fema p 431.
While tornado doors are similar in appearance to standard steel doors they are highly engineered products and cannot be substituted by heavy gauge standard steel doors.
Fema p 361 safe rooms for tornadoes and hurricanes.
Debris impact testing for fema p 320.
This design is based on extensive research on the cause and effects of windstorm damage to buildings.
Guidance for community and residential safe rooms 2015 the nssa is educating the public about the safety of storm shelter doors and advocating that shelter door manufacturers clearly identify a door that is intended for storm shelter application.