Walls less than 5 from the property line are required to have a one hour fire rating.
Fire separation distance between roofs.
Fire area appears in the building code mostly in chapter 9 where it is used as a threshold for requiring either fire separation or fire sprinkler systems.
8 thick masonry was a common way to do firewalls in my area.
If the separation is between 5 feet and 10 feet the requirements ease slightly for all construction types except ia.
Typical fire separation requirements for townhouses is a 2 hour fire rating.
To the centerline of a street an alley or public way.
Exterior walls of dwellings garages and accessory buildings must maintain a 5 minimum separation distance from the property line or otherwise be fire protected.
Fire separation distance is measured from the face of the building to the property line centerline of a street or alley or to an imaginary line between two buildings.
Fire separation distance fsd is he distance measured from the foundation wall or face of wall framing whichever is closer to one of the following.
I think 1 2 thick gypsum board is probably also required at each side on the wall framing adjacent to the 2 shaft liner system.
The occupancy group of the building determines whether the exterior wall must be 1 2 or 3 hour construction.
4 replacing of roof material with fire proof material and closing of existing windows with fire proof concrete wall.
To the closest interior lot line.
Depending on the fire separation distance degree of opening protection and percentage of openings the distance required between buildings on the same lot can vary anywhere from 0 feet to 60 feet based on ibc table 705 8.
External walls including gables required to be fire resisting referred to in 3 7 1 3 or 3 7 1 6 must extend to the underside of a non combustible roof covering or non combustible eaves lining see figure 3 7 1 3 and must.
Gypsum board party walls are more common now.
For example section 903 2 9 states that one threshold of sprinklering the entire building is when such a building contains a group s 1 fire area of greater than 12 000 square feet.
To an imaginary line between two buildings on the lot.
This recommended practice provides recommendations concerning separation distances between buildings to limit exterior fire spread based on exterior openings and other construction features.
Where the fire separation distance is five feet or less the construction type is not relevant.